An ultra-sensitive and specific nanoplasmonic-enhanced isothermal amplification platform for the ultrafast point-of-care testing of SARS-CoV-2.
An ultra-sensitive and specific nanoplasmonic-enhanced isothermal amplification platform for the ultrafast point-of-care testing of SARS-CoV-2.
复制标题
超灵敏、特异的纳米等离子增强等温扩增平台,用于 SARS-CoV-2 的超快现场护理测试。
DOI:
10.1016/j.cej.2022.138822
复制
发表时间:
2023-01-01
影响因子:
15.1
通讯作者:
Liu, Gang L.
中科院分区:
文献类型:
--
作者:
Liu, Juxiang;Chen, Ping;Hu, Xulong;Huang, Liping;Geng, Zhi;Xu, Hao;Hu, Wenjun;Wang, Lin;Wu, Ping;Liu, Gang L.
关键词:
The novel mutations attributed by the high mutagenicity of the SARS-CoV-2 makes its prevention and treatment challenging. Developing an ultra-fast, point-of-care-test (POCT) protocol is critical for responding to large-scale spread of SARS-CoV-2 in public places and in resource-poor remote areas. Here, we developed a nanoplasmonic enhanced isothermal amplification (NanoPEIA) strategy that combines a nanoplasmonic sensor with isothermal amplification. The novel strategy provides an ideal easy-to operate detection platform for obtaining accurate, ultra-fast and high-throughput (96 samples can be tested together) data. For clinical samples with viral detection at Ct value <25, the entire process (including sample preparation, virus lysis, detection, and data analysis) can be completed within six minutes. The method is also appropriate for detection of SARS-CoV-2 γ-coronavirus mutants. The NanoPEIA method was validated using clinical samples from 21 patients with SARS-CoV-2 infection and 31 healthy individuals. The detection result on the 52 clinical samples for SARS-CoV-2 showed that the NanoPEIA platform had a 100% sensitivity for N and orf1ab genes, which was higher than those obtained using RT-qPCR (88.9% and 90.0%, respectively). The specificities of 31 clinical negative samples were 92.3% and 91.7% for the N gene and the orf1ab gene, respectively. The limits of detection (LoD) of the clinical samples were 28.3 copies/mL and 23.3 copies/mL for the N gene and the orf1ab gene, respectively. The efficient NanoPEIA detection strategy facilitates real-time detection and visualization within ultrashort durations and can be applied for POCT diagnosis in resource-poor and highly populated areas.
登录
查看更多内容
影响因子:
3.1
作者:
Aupaix A;Lazarova E;Chemais M
通讯作者:
Chemais M
影响因子:
16.6
作者:
Ding X;Yin K;Li Z;Lalla RV;Ballesteros E;Sfeir MM;Liu C
通讯作者:
Liu C
影响因子:
9.3
作者:
Behrmann, Ole;Bachmann, Iris;Hufert, Frank T.
通讯作者:
Hufert, Frank T.
影响因子:
3.8
作者:
Andries, Anne-Claire;Duong, Veasna;Buchy, Philippe
通讯作者:
Buchy, Philippe
影响因子:
6.2
作者:
Li J;Hu X;Wang X;Yang J;Zhang L;Deng Q;Zhang X;Wang Z;Hou T;Li S
通讯作者:
Li S