Refinement of triclinic lysozyme: II. The method of stereochemically restrained least squares.
Refinement of triclinic lysozyme: II. The method of stereochemically restrained least squares.
复制标题
三斜溶菌酶的精制:II.
DOI:
10.1107/s0108768189009195
复制
发表时间:
1990
期刊:
影响因子:
--
通讯作者:
Jensen,LH
中科院分区:
文献类型:
--
作者:
Ramanadham,M;Sieker,LC;Jensen,LH
Refinement of triclinic lysozyme by restrained least squares against the 2/~ resolution X-ray data is described, beginning with the model from cycle 17 of the preceding paper [Hodsdon, Brown, Sieker & Jensen (1990). Acta Cryst. B46, 54-62]. After 20 refinement cycles, R stood at 0.172. Nevertheless, serious errors involving both main-chain and side-chain atoms still remained, requiring numerous model rebuilding sessions interleaved with refinement cycles. After 63 cycles R= 0.124 for the model which includes all protein atoms, 249 water oxygen sites and five nitrate ions. Although the overall B is relatively low, 10.5 A, 2, B's for atoms in the region of residues 101-103, toward the termini of some of the longer side chains, and in the region of the C termi-nus of the main chain exceed 20 A2, indicating relatively high atomic mobilities, disorder, or remaining errors in the model.