RELATIONSHIP BETWEEN THE AMPLITUDES OF THE B-WAVE AND THE A-WAVE AS A USEFUL INDEX FOR EVALUATING THE ELECTRORETINOGRAM
RELATIONSHIP BETWEEN THE AMPLITUDES OF THE B-WAVE AND THE A-WAVE AS A USEFUL INDEX FOR EVALUATING THE ELECTRORETINOGRAM
复制标题
DOI:
10.1136/bjo.67.7.443
复制
发表时间:
1983-01-01
影响因子:
4.1
通讯作者:
PERLMAN, I
中科院分区:
文献类型:
--
作者:
PERLMAN, I
The methods for the assessment of the electroretinogram (ERG) [from humans] make the exchange of data between laboratories difficult owing to differences in photostimulation and recording techniques. In addition to present techniques the b wave to a wave relationship may be a useful index for evaluating the ERG. The ERG responses evoked by relatively bright flashes are recorded in the dark-adapted state. A plot of the b wave amplitude as a function of the a wave amplitude describes the functional integrity of the retina. A normally functioning retina should elicit an ERG response that fits the normal curve regardless of the apparatus used for ERG recording. The only constraint was the use of full-field illumination. This method was based on physiological considerations regarding the origin of the ERG components. Such a method will facilitate data exchange between centers and can also be used for clinical assessment of the retina.