Sialolithiasis: MR sialography of the submandibular duct--an alternative to conventional sialography and US?
Sialolithiasis: MR sialography of the submandibular duct--an alternative to conventional sialography and US?
复制标题
唾液结石:下颌下管的 MR 唾液造影——传统唾液造影和超声的替代方法?
DOI:
10.1148/radiology.216.3.r00se12665
复制
发表时间:
2000
期刊:
影响因子:
19.7
通讯作者:
M. Reiser
中科院分区:
文献类型:
--
作者:
L. Jäger;F. Menauer;Nikolaus Holzknecht;Verena Scholz;G. Grevers;M. Reiser
PURPOSE
To determine the value of magnetic resonance (MR) sialography for the diagnosis of sialolithiasis by comparing results prospectively with those of ultrasonography (US) and digital sialography.
MATERIALS AND METHODS
MR sialography was prospectively performed with T2-weighted three-dimensional (3D) constructive interference in steady-state (CISS) and rapid acquisition with relaxation-enhancement (RARE) sequences in 24 patients suspected of having sialolithiasis. Evoked salivation was used as contrast material. T1-weighted spin-echo and T2-weighted turbo spin-echo MR imaging also were performed. The results were then compared with those of US and digital sialography, with the latter as standard of reference.
RESULTS
The 3D CISS images were significantly (P: <.05) superior to RARE images for demonstrating the submandibular ductal system, followed by T2-weighted turbo spin-echo images (P: <.01) and T1-weighted spin-echo images (P: <.001). The sensitivity and specificity were 100% and 80%, respectively, for CISS MR sialography and 80% and 100%, respectively, for RARE MR imaging. The sensitivity and specificity of US were both 80%.
CONCLUSION
MR sialography with evoked salivation is noninvasive and allows delineation of the submandibular ductal system and detection of sialoliths with accuracy that is similar to that of digital sialography and superior to that of US.