Accelerating dynamic magnetic resonance imaging (MRI) for lung tumor tracking based on low-rank decomposition in the spatial-temporal domain: a feasibility study based on simulation and preliminary prospective undersampled MRI.
Accelerating dynamic magnetic resonance imaging (MRI) for lung tumor tracking based on low-rank decomposition in the spatial-temporal domain: a feasibility study based on simulation and preliminary prospective undersampled MRI.
复制标题
DOI:
10.1016/j.ijrobp.2013.11.217
复制
发表时间:
2014-03-01
影响因子:
7
通讯作者:
Sheng, Ke
中科院分区:
文献类型:
--
作者:
Sarma, Manoj;Hu, Peng;Rapacchi, Stanislas;Ennis, Daniel;Thomas, Albert;Lee, Percy;Kupelian, Patrick;Sheng, Ke
To evaluate a low-rank decomposition method to reconstruct down-sampled k-space data for the purpose of tumor tracking. Seven retrospective lung cancer patients were included in the simulation study. The fully-sampled k-space data were first generated from existing 2-dimensional dynamic MR images and then down-sampled by 5 × −20 × before reconstruction using a Cartesian undersampling mask. Two methods, a low-rank decomposition method using combined dynamic MR images (k-t SLR based on sparsity and low-rank penalties) and a total variation (TV) method using individual dynamic MR frames, were used to reconstruct images. The tumor trajectories were derived on the basis of autosegmentation of the resultant images. To further test its feasibility, k-t SLR was used to reconstruct prospective data of a healthy subject. An undersampled balanced steady-state free precession sequence with the same undersampling mask was used to acquire the imaging data. In the simulation study, higher imaging fidelity and low noise levels were achieved with the k-t SLR compared with TV. At 10 × undersampling, the k-t SLR method resulted in an average normalized mean square error <0.05, as opposed to 0.23 by using the TV reconstruction on individual frames. Less than 6% showed tracking errors >1 mm with 10 × down-sampling using k-t SLR, as opposed to 17% using TV. In the prospective study, k-t SLR substantially reduced reconstruction artifacts and retained anatomic details. Magnetic resonance reconstruction using k-t SLR on highly undersampled dynamic MR imaging data results in high image quality useful for tumor tracking. The k-t SLR was superior to TV by better exploiting the intrinsic anatomic coherence of the same patient. The feasibility of k-t SLR was demonstrated by prospective imaging acquisition and reconstruction.
登录
查看更多内容
DOI:
10.1102/1470-7330.2006.9027
发表时间:
2006-10-31
期刊:
Cancer imaging : the official publication of the International Cancer Imaging Society
影响因子:
--
作者:
Kauczor HU;Plathow C
通讯作者:
Plathow C
影响因子:
3
作者:
Candes, Emmanuel J.;Recht, Benjamin
通讯作者:
Recht, Benjamin
影响因子:
10.6
作者:
Lingala SG;Hu Y;DiBella E;Jacob M
通讯作者:
Jacob M
影响因子:
2.5
作者:
Candès, EJ;Romberg, J;Tao, T
通讯作者:
Tao, T
影响因子:
3.8
作者:
Fallone, B. G.;Murray, B.;Tymofichuk, D.
通讯作者:
Tymofichuk, D.