DETERMINATION OF PERMEABILITY FROM IMPEDANCE MEASUREMENT USING VECTOR NETWORK ANALYZER
DETERMINATION OF PERMEABILITY FROM IMPEDANCE MEASUREMENT USING VECTOR NETWORK ANALYZER
复制标题
使用矢量网络分析仪通过阻抗测量确定磁导率
DOI:
--
复制
发表时间:
2012
期刊:
影响因子:
--
通讯作者:
R. Dosoudil
中科院分区:
文献类型:
--
作者:
R. Dosoudil
This study treats the optimised one-port (reflection coefficient) and two-port (shunt-through/series-through) measurement methods for complex permeability determination of solid soft magnetic materials using a vector network analyzer (VNA) at frequencies from 9 kHz to 6.5 GHz. The principle of measurement methods, the relationships of measured phasor voltage ratio (Sparameter) to complex impedance, and permeability calculation equations are presented. Each method gives good measurement sensitivity at the impedance range where the measured ac voltage at the VNA’s receiver significantly varies. For permeability evaluation, the shunt-through method provides the best sensitivity and stability and thus is suitable for both low and high permeability materials.