Estimating the diameter/thickness of a pipe using the primary wave velocity of a hollow cylindrical guided wave
Estimating the diameter/thickness of a pipe using the primary wave velocity of a hollow cylindrical guided wave
复制标题
使用空心圆柱形导波的主波速估计管道的直径/厚度
DOI:
10.1063/1.1781353
复制
发表时间:
2004
影响因子:
4
通讯作者:
N. Chubachi
中科院分区:
文献类型:
--
作者:
H. Nishino;M. Takemoto;N. Chubachi
A method for measuring the diameter/thickness (d∕t) of a pipe using a characteristic of a hollow cylindrical guided wave (HCGW) is presented. The HCGW is an ultrasonic guided wave propagating along a pipe. In the first part of this letter, we briefly show that the primary wave (first-arriving wave packet from an impulse source) of the HCGW achieves a faster group velocity for a larger d∕t. Experimental verifications were carried out for aluminum pipes (several different d∕t’s) using a laser ultrasonic method to generate the HCGW. The experimental results are in fairly good agreement with the theoretical prediction described.