How we perform delayed enhancement imaging
How we perform delayed enhancement imaging
复制标题
DOI:
10.1081/jcmr-120022267
复制
发表时间:
2003-01-01
影响因子:
6.4
通讯作者:
Judd, RM
中科院分区:
文献类型:
--
作者:
Kim, RJ;Shah, DJ;Judd, RM
Recently, numerous studies have demonstrated the effectiveness of a segmented inversion recovery fast gradient echo (seg IR-FGE) sequence for differentiating injured from normal myocardium. This technique for delayed enhancement imaging has been shown to be effective in identifying the presence and extent of myocardial infarction, as well as predicting improvement in contractile function after coronary revascularization. In this article we outline the procedure of delayed enhancement imaging performed at our center, describe the seg IR-FGE sequence in more detail, including our process for choosing sequence settings, review our process of image interpretation, and highlight potential pitfalls (and techniques to overcome them) that we have encountered in our experience with performing the technique in over 1500 patients.