Unbalanced Grid Fault Ride-Through Control for Single-Stage Photovoltaic Inverters
Unbalanced Grid Fault Ride-Through Control for Single-Stage Photovoltaic Inverters
复制标题
单级光伏逆变器的不平衡电网故障穿越控制
DOI:
10.1109/tpel.2015.2453275
复制
发表时间:
2016-04
影响因子:
6.7
通讯作者:
F. Neves;M. Carrasco;F. Mancilla–David;G. Azevedo;V. Santos
中科院分区:
文献类型:
--
作者:
F. Neves;M. Carrasco;F. Mancilla–David;G. Azevedo;V. Santos
Integration of distributed generation (DG) such as photovoltaics (PV) represents a challenge for the traditional operation of distribution power systems. As the installed power of DGs grows, grid codes are being modified to involve DGs in the provision of ancillary services. This includes the ability to ride-through large disturbances. In this paper, the behavior of a single-stage PV system under unbalanced voltage conditions is studied, and a fault ride-through control scheme is proposed which is able to support the grid through the injection of reactive power. Furthermore, adjustable power quality is enabled as a tradeoff between power ripple and current harmonics. The control scheme makes use of a current controller based on the space vector Fourier transform concept. No rotational transformation is required, and zero steady-state error is ensured when tracking distorted current references. The controller was tested in detailed PSCAD/EMTDC computer simulations, and implemented in a real grid-connected PV system to demonstrate its performance under unbalanced voltage conditions.