Synovial Fluid Metal Ion Levels are Superior to Blood Metal Ion Levels in Predicting an Adverse Local Tissue Reaction in Failed Total Hip Arthroplasty.
Synovial Fluid Metal Ion Levels are Superior to Blood Metal Ion Levels in Predicting an Adverse Local Tissue Reaction in Failed Total Hip Arthroplasty.
复制标题
在预测全髋关节置换术失败的局部组织不良反应方面,滑液金属离子水平上级于血液金属离子水平。
DOI:
10.1016/j.arth.2021.04.034
复制
发表时间:
2021-09
影响因子:
3.5
通讯作者:
Berry, Daniel J.
中科院分区:
文献类型:
--
作者:
Houdek, Matthew T.;Taunton, Michael J.;Wyles, Cody C.;Jannetto, Paul J.;Lewallen, David G.;Berry, Daniel J.
Adverse local tissue reactions (ALTR) are associated with total hip arthroplasty (THA) failure in patients with metal-on-metal (MoM) bearings and/or taper corrosion, which can also occur in metal-on-polyethylene (MoP) articulations. Patients are monitored with blood cobalt (Co) and chromium (Cr) concentrations which do not always correlate with the degree of soft-tissue reaction at revision THA. The purpose of this study was to determine how the blood and prosthetic hip synovial fluid levels of Co and Cr correlate with one another, and determine which concentration is more predictive of ALTR. Synovial fluid and blood samples were collected at the time of revision THA in patients with (n=26) and without ALTR (n=27). Whole blood, serum and synovial fluid metal ion concentrations were correlated with one another and clinical findings. The ratio of synovial fluid to whole blood Co concentration in ALTR and non-ALTR hips was 120:1 and 18:1 (p=0.006). The mean ratio of synovial fluid to whole blood Cr concentration in ALTR and non-ALTR hips was 414:1 and 24:1 (p=0.01). The mean synovial fluid Co/Cr concentrations were elevated in patients with ALTR compared to those without (2,007.3 vs. 12.4 ppb, P=0.007), and (3,188.2 vs. 10.3 ppb, P=0.02). The synovial fluid Co concentration was the most accurate test for detecting ALTR (Cut off: 19.75 PPB, AUC 0.973). In patients with ALTR, synovial fluid Co and Cr levels were 120 times higher and 414 times higher than whole blood Co and Cr levels. Synovial fluid Co ion concentration was the most accurate in predicting ALTR.
登录
查看更多内容
影响因子:
4.6
作者:
Sidaginamale, R. P.;Joyce, T. J.;Langton, D. J.
通讯作者:
Langton, D. J.
影响因子:
3.7
作者:
Durrani SK;Noble PC;Sampson B;Panetta T;Liddle AD;Sabah SA;Chan NK;Skinner JA;Hart AJ
通讯作者:
Hart AJ
影响因子:
3.5
作者:
Nodzo, Scott R.;Esposito, Christina I.;Padgett, Douglas E.
通讯作者:
Padgett, Douglas E.
DOI:
10.1302/0301-620x.93b10.26249
发表时间:
2011-10-01
影响因子:
--
作者:
Hart, A. J.;Sabah, S. A.;Skinner, J. A.
通讯作者:
Skinner, J. A.
影响因子:
3.5
作者:
Griffin, William L.;Fehring, Thomas K.;Dennos, Anne C.
通讯作者:
Dennos, Anne C.