In-house validation of a liquid chromatography tandem mass spectrometry method for the analysis of lipophilic marine toxins in shellfish using matrix-matched calibration.

In-house validation of a liquid chromatography tandem mass spectrometry method for the analysis of lipophilic marine toxins in shellfish using matrix-matched calibration.
复制标题

DOI:
10.1007/s00216-010-3886-2
复制
发表时间:
2010-08
影响因子:
4.3
通讯作者:
de Boer, Jacob
de Boer, Jacob
中科院分区:
化学2区
文献类型:
--
作者:
Gerssen, Arjen;van Olst, Erik H. W.;Mulder, Patrick P. J.;de Boer, Jacob

文献摘要

参考文献

被引文献

相似文献

A liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the quantitative analysis of lipophilic marine toxins in shellfish extracts (mussel, oyster, cockle and clam) was validated in-house using European Union (EU) Commission Decision 2002/657/EC as a guideline. The validation included the toxins okadaic acid (OA), yessotoxin (YTX), azaspiracid-1 (AZA1), pectenotoxin-2 (PTX2) and 13-desmethyl spirolide-C (SPX1). Validation was performed at 0.5, 1 and 1.5 times the current EU permitted levels, which are 160 µg kg-1 for OA, AZA1 and PTX2 and 1,000 µg kg-1 for YTX. For SPX1, 400 µg kg-1 was chosen as the target level as no legislation has been established yet for this compound. The method was validated for determination in crude methanolic shellfish extracts and for extracts purified by solid-phase extraction (SPE). Extracts were also subjected to hydrolysis conditions to determine the performance of the method for OA and dinophysistoxin esters. The toxins were quantified against a set of matrix-matched standards instead of standard solutions in methanol. To save valuable standard, methanolic extract instead of the homogenate was spiked with the toxin standard. This was justified by the fact that the extraction efficiency is high for all relevant toxins (above 90%). The method performed very well with respect to accuracy, intraday precision (repeatability), interday precision (within-laboratory reproducibility), linearity, decision limit, specificity and ruggedness. At the permitted level the accuracy ranged from 102 to 111%, the repeatability from 2.6 to 6.7% and the reproducibility from 4.7 to 14.2% in crude methanolic extracts. The crude extracts performed less satisfactorily with respect to the linearity (less than 0.990) and the change in LC-MS/MS sensitivity during the series (more than 25%). SPE purification resulted in greatly improved linearity and signal stability during the series. Recently the European Food Safety Authority (EFSA) has suggested that to not exceed the acute reference dose the levels should be below 45 µg kg-1 OA equivalents and 30 µg kg-1 AZA1 equivalents. A single-day validation was successfully conducted at these levels. If the regulatory levels are lowered towards the EFSA suggested values, the official methods prescribed in legislation (mouse and rat bioassay) will no longer be sensitive enough. The validated LC-MS/MS method presented has the potential to replace these animal tests. The online version of this article (doi:10.1007/s00216-010-3886-2) contains supplementary material, which is available to authorized users.
DOI: 10.1016/s0041-0101(03)00094-1
发表时间: 2003-07-01
期刊: TOXICON
影响因子: 2.8
作者:
Ciminiello, P;Dell'Aversano, C;Boni, L
通讯作者: Boni, L
DOI: 10.2903/j.efsa.2008.589
发表时间: 2008-01-01
期刊: EFSA JOURNAL
影响因子: 3.3
作者:
通讯作者: --
DOI: 10.1080/02652030210126398
发表时间: 2002-06-01
期刊: FOOD ADDITIVES AND CONTAMINANTS
影响因子: --
作者:
James, KJ;Lehane, M;Furey, A
通讯作者: Furey, A
DOI: 10.1016/j.toxicon.2007.07.003
发表时间: 2007-12-01
期刊: TOXICON
影响因子: 2.8
作者:
Rundberget, Thomas;Sandvik, Morten;Miles, Christopher O.
通讯作者: Miles, Christopher O.
DOI: 10.1016/s0021-9673(00)01047-5
发表时间: 2001-01-12
影响因子: 4.1
作者:
Goto, H;Igarashi, T;Yasumoto, T
通讯作者: Yasumoto, T