An End-to-End Energy-Efficient Approach for Intake Detection With Low Inference Time Using Wrist-Worn Sensor.

An End-to-End Energy-Efficient Approach for Intake Detection With Low Inference Time Using Wrist-Worn Sensor.
复制标题

使用腕戴式传感器进行低推理时间的摄入检测的端到端节能方法。

DOI:
10.1109/jbhi.2023.3276629
复制
发表时间:
2023
影响因子:
7.7
通讯作者:
Alshurafa,Nabil
Alshurafa,Nabil
中科院分区:
工程技术1区
文献类型:
--
作者:
Wei,Boyang;Zhang,Shibo;Diao,Xingjian;Xu,Qiuyang;Gao,Yang;Alshurafa,Nabil

文献摘要

相似文献

Automated detection of intake gestures with wearable sensors has been a critical area of research for advancing our understanding and ability to intervene in people's eating behavior. Numerous algorithms have been developed and evaluated in terms of accuracy. However, ensuring the system is not only accurate in making predictions but also efficient in doing so is critical for real-world deployment. Despite the growing research on accurate detection of intake gestures using wearables, many of these algorithms are often energy inefficient, impeding on-device deployment for continuous and real-time monitoring of diet. This article presents a template-based optimized multicenter classifier that enables accurate intake gesture detection while maintaining low-inference time and energy consumption using a wrist-worn accelerometer and gyroscope. We designed an Intake Gesture Counter smartphone application (CountING) and validated the practicality of our algorithm against seven state-of-the-art approaches on three public datasets (In-lab FIC, Clemson, and OREBA). Compared with other methods, we achieved optimal accuracy (81.60% F1 score) and very low inference time (15.97 msec per 2.20-sec data sample) on the Clemson dataset, and among the top performing algorithms, we achieve comparable accuracy (83.0% F1 score compared with 85.6% in the top performing algorithm) but superior inference time (13.8x faster, 33.14 msec per 2.20-sec data sample) on the In-lab FIC dataset and comparable accuracy (83.40% F1 score compared with 88.10% in the top-performing algorithm) but superior inference time (33.9x faster, 16.71 msec inference time per 2.20-sec data sample) on the OREBA dataset. On average, our approach achieved a 25-hour battery lifetime (44% to 52% improvement over state-of-the-art approaches) when tested on a commercial smartwatch for continuous real-time detection. Our approach demonstrates an effective and efficient method, enabling real-time intake gesture detection using wrist-worn devices in longitudinal studies.