Diagnostic Performance and Safety of Positron Emission Tomography Using 18F-Fluciclovine in Patients with Clinically Suspected High- or Low-grade Gliomas: A Multicenter Phase IIb Trial.

Diagnostic Performance and Safety of Positron Emission Tomography Using 18F-Fluciclovine in Patients with Clinically Suspected High- or Low-grade Gliomas: A Multicenter Phase IIb Trial.
复制标题

DOI:
10.22038/aojnmb.2016.7869
复制
发表时间:
2017-01-01
影响因子:
--
通讯作者:
Kubomura, Kan
Kubomura, Kan
中科院分区:
其他
文献类型:
--
作者:
Wakabayashi, Toshihiko;Iuchi, Toshihiko;Kubomura, Kan

文献摘要

被引文献

相似文献

目的:本研究目的是评估使用新型示踪剂18F-氟氯梵(anti-[18F]FACBC)的正电子发射断层扫描(PET)对胶质瘤的诊断性能,并评估该示踪剂在临床疑似胶质瘤患者中的安全性。方法:对40例临床怀疑为高或低级别胶质瘤的患者进行抗[18F]FACBC治疗,并进行PET成像。获得t1加权、对比增强t1加权和流体衰减反转恢复(或t2加权)磁共振成像(MRI)扫描,以计划组织收集。从“使用抗[18F]FACBC PET成像显示但未使用对比增强t1加权成像的区域”或“使用抗[18F]FACBC-PET成像和对比增强t1加权成像显示的区域”收集组织,进行组织病理学检查,以评估抗[18F]FACBC-PET对胶质瘤的诊断准确性。结果:抗[18F]FACBC-PET成像对使用抗[18F]FACBC-PET成像而未使用对比增强t1 -加权成像的区域的胶质瘤阳性预测值为100.0%(26/26),同时使用对比增强t1 -加权成像和抗[18F]FACBC-PET成像的区域的阳性预测值为87.5%(7/8)。在接受抗[18F]FACBC治疗的40例患者中,有7例(17.5%)发生了12例不良事件。5例患者中有5例事件被认为是药物不良反应;然而,没有一个事件是严重的,除了一个之外,所有的事件都是自发的,无需治疗。结论:这项IIb期试验表明,anti-[18F]FACBC-PET成像可有效检测对比增强t1加权MRI无法显示的区域的胶质瘤,且示踪剂耐受性良好。
OBJECTIVES: The study objective was to assess the diagnostic performance of positron emission tomography (PET) for gliomas using the novel tracer 18F-fluciclovine (anti-[18F]FACBC) and to evaluate the safety of this tracer in patients with clinically suspected gliomas.METHODS: Anti-[18F]FACBC was administered to 40 patients with clinically suspected high- or low-grade gliomas, followed by PET imaging. T1-weighted, contrast-enhanced T1-weighted, and fluid-attenuated inversion recovery (or T2-weighted) magnetic resonance imaging (MRI) scans were obtained to plan for the tissue collection. Tissues were collected from either "areas visualized using anti-[18F]FACBC PET imaging but not using contrast-enhanced T1-weighted imaging" or "areas visualized using both anti-[18F]FACBC-PET imaging and contrast-enhanced T1-weighted imaging" and were histopathologically examined to assess the diagnostic accuracy of anti-[18F]FACBC-PET for gliomas.RESULTS: The positive predictive value of anti-[18F]FACBC-PET imaging for glioma in areas visualized using anti-[18F]FACBC-PET imaging, but not visualized using contrast-enhanced T1-weighted images, was 100.0% (26/26), and the value in areas visualized using both contrast-enhanced T1-weighted imaging and anti-[18F]FACBC-PET imaging was 87.5% (7/8). Twelve adverse events occurred in 7 (17.5%) of the 40 patients who received anti-[18F]FACBC. Five events in five patients were considered to be adverse drug reactions; however, none of the events were serious, and all except one resolved spontaneously without treatment.CONCLUSION: This Phase IIb trial showed that anti-[18F]FACBC-PET imaging was effective for the detection of gliomas in areas not visualized using contrast-enhanced T1-weighted MRI and the tracer was well tolerated.