New traceability concept in RF inductance measurements
New traceability concept in RF inductance measurements
复制标题
射频电感测量中的新可追溯性概念
DOI:
10.1109/cpem.2018.8501064
复制
发表时间:
2018
期刊:
影响因子:
--
通讯作者:
Masahiro Horibe
中科院分区:
文献类型:
--
作者:
Atsushi Domae;Masahiro Horibe
National Metrology Institute of Japan (NMIJ) is developing a reference inductance standard using air dielectric coaxial transmission lines that can be used beyond MHz. We report on the structure and traceability system of this reference inductance standard. NMIJ is also developing an inductance measurement method using group delay measurement. A 50 nH reference inductance standard was developed and the inductance measurement method using group delay verified.