Ultrawide-angle retinal imaging and retinal detachment.

Ultrawide-angle retinal imaging and retinal detachment.
复制标题

DOI:
10.1080/08820530601162867
复制
发表时间:
2007-01-01
影响因子:
1.7
通讯作者:
Singh, J
Singh, J
中科院分区:
医学4区
文献类型:
--
作者:
Anderson, L;Friberg, T R;Singh, J

文献摘要

被引文献

相似文献

目得:为了说明实用程序的超广角眼底成像在记录的临床过程中的视网膜detachment.DESIGN:观察case report.METHOD:一个20岁的男子高度近视眼和一个盲人的眼睛注意到视网膜脱离的症状,并与超广角眼底成像设备(Optos P200)成像。成像进行后巩膜扣带术和之前和之后额外的vitreoretinal surgery.RESULTS:超广角图像是有用的划定视网膜脱离的程度,即使在存在的眼内gas.CONCLUSION:能够快速成像眼底以及前赤道有利于临床管理,并可能证明特别有用的电子记录保存。
PURPOSE: To illustrate the utility of ultrawide-angle fundus imaging in documenting the clinical course of a retinal detachment.DESIGN: Observational case report.METHOD: A 20-year-old man with high myopia and a blind fellow eye noted symptoms of retinal detachment and was imaged with an ultrawide-angle fundus imaging device (Optos P200). Imaging was performed after scleral buckling and before and after additional vitreoretinal surgery.RESULTS: Ultrawide-angle images were useful in delineating the extent of retinal detachment even in the presence of intraocular gas.CONCLUSION: The ability to rapidly image the ocular fundus well anterior to the equator facilitates clinical management and may prove particularly useful in electronic record keeping.