Technical Note: REFIR-PAD level 1 data analysis and performance characterization
Technical Note: REFIR-PAD level 1 data analysis and performance characterization
复制标题
技术说明:REFIR-PAD 1 级数据分析和性能表征
DOI:
--
复制
发表时间:
2008
期刊:
影响因子:
--
通讯作者:
L. Palchetti
中科院分区:
文献类型:
--
作者:
G. Bianchini;L. Palchetti
The outgoing long-wave radiation from the Earth's atmosphere in the far infrared spectral region is mostly unexplored, while is well recognized that the water vapour contribution to greenhouse trapping is dominant in this region. The Radiation Explorer in the Far InfraRed (RE- FIR) study has proven the feasibility of a space-borne Fourier transform spectrometer able to perform the measurement in the 100-1100 cm 1 range with a resolution of 0.5 cm 1 . Fol- lowing this work a prototype of the spectrometer named REFIR-PAD (Prototype for Applications and Development) has been developed to observe the atmospheric radiance from both ground-based sites and from stratospheric balloon plat- forms. In this work we describe the REFIR-PAD level 1 data analysis procedure, that, starting from raw instrumental data produces the calibrated atmospheric spectral radiance. Per- formances of the procedure are also described.