Design of practical T2-selective RF excitation (TELEX) pulses
Design of practical T2-selective RF excitation (TELEX) pulses
复制标题
DOI:
10.1002/mrm.1910400615
复制
发表时间:
1998-12-01
影响因子:
3.3
通讯作者:
Wright, GA
中科院分区:
文献类型:
--
作者:
Sussman, MS;Pauly, JM;Wright, GA
Traditional T-2-based imaging techniques are geared toward imaging long-T-2 species. Traditional techniques are, therefore, not optimal in clinical situations where the information of interest lies in the short-T-2 species. T-2-selective RF excitation (TELEX) is a technique for obtaining a T-2-based contrast that highlights short-T-2 values while suppressing long-T-2 values-opposite to traditional T-2 contrast. Previously, TELEX has been demonstrated qualitatively to highlight only very short-T-2 values (T-2 approximate to 0.001 s). When applied to longer T-2 values (T-2 greater than or equal to 0.01 s), TELEX becomes sensitive to Delta B-0 non-uniformities. This restricts its application to problems in which the T-2 of interest is very short. In this study, TELEX is characterized quantitatively. Furthermore, a bandwidth broadening scheme is developed that reduces the Delta B-0 sensitivity of TELEX This permits the technique to be applied to longer T-2 values. The capabilities and limitations of a practical implementation of TELEX are discussed.