Measurement of Airborne Bacteria and Endotoxin Generated During Dental Cleaning
Measurement of Airborne Bacteria and Endotoxin Generated During Dental Cleaning
复制标题
DOI:
10.1080/15459620802633957
复制
发表时间:
2009-01-01
影响因子:
2
通讯作者:
Duchaine, Caroline
中科院分区:
文献类型:
--
作者:
Dutil, Steve;Meriaux, Anne;Duchaine, Caroline
Dynamic dental instruments generate abundant aerosols in the work environment. Dental unit waterlines (DUWL) support a large microbial population and can be a significant source of bioaerosols generated during dental treatments. This study was conducted to characterize bioaerosol generation during dental treatments performed in standardized conditions. Culture-based method (R2A, and blood agar with and without O-2) and fluorescence microscopy were used. Dental cleaning procedures were performed in an isolated treatment room with controlled ventilation rate. Andersen microbial samplers were used to collect culturable bioaerosols generated before ( baseline), during, and after 2 hr of dental treatments. Inhalable dust samplers were used to measure total bioaerosols content in dental hygienist's and patients' breathing zones. AGI-30 were used for the collection of the endotoxin. The use of fluorescence microscopy in combination with culture demonstrated that dental staff and patients were exposed to up to 1.86 E+05 bacteria/m(3) generated during treatments. Fortunately, bioaerosols returned to baseline within 2 hr after the dental procedures. The small diameter of the aerosols generated (< 1 mu m) suggests that the risk of contact between the aerosolized bacteria and the respiratory system of exposed individuals is likely to occur.