Electrochemical immunoassay for the protein biomarker mucin 1 and for MCF-7 cancer cells based on signal enhancement by silver nanoclusters

Electrochemical immunoassay for the protein biomarker mucin 1 and for MCF-7 cancer cells based on signal enhancement by silver nanoclusters
复制标题

基于银纳米簇信号增强的蛋白质生物标志物粘蛋白 1 和 MCF-7 癌细胞的电化学免疫分析

DOI:
10.1007/s00604-015-1471-2
复制
发表时间:
2015-06-01
期刊:
影响因子:
5.7
通讯作者:
Yang, Minghui
Yang, Minghui
中科院分区:
化学2区
文献类型:
--
作者:
Guo, Qingjun;Li, Xiangzhi;Yang, Minghui

文献摘要

被引文献

相似文献

描述了用于检测蛋白质生物标志物粘蛋白1(MUC-1)和其中MUC-1过表达的MCF-7型乳腺癌细胞的电化学免疫测定。该方法是基于使用的银纳米簇(银-NC)作为信号探针。在序列为5 '-GCAGTTGATCCTTTGGATACCTGG-C-12- 3'的DNA链存在下,通过化学还原合成Ag-NC。该链含有粘蛋白1适体(GCAGTTGATCCTTTGGATACCCTGG),可特异性结合MUC 1和模板(C-12),用于合成Ag-NC。该测定包括以下步骤:(1)通过将针对MUC-1的抗体固定在玻碳电极上来构建免疫传感器;(2)添加含有MUC-1的样品;(3)添加Ag-NC;(4)通过银增强过程(在Ag-NC上沉积金属银)进行信号放大;(5)通过方波伏安法进行测量。在0.11 V(vs. SCE)电位下测量的电流与MUC-1浓度在1至500 nM范围内呈对数相关,检测限为0.5 nM。我们还证明,由于细胞表面存在MUC-1蛋白,因此可以通过该方法以高灵敏度(50个细胞/mL)检测MCF-7癌细胞。
An electrochemical immunoassay is described for the detection of the protein biomarker mucin 1 (MUC-1) and of breast cancer cells of type MCF-7 where MUC-1 is overexpressed. The method is based on the use of silver nanoclusters (Ag-NCs) acting as a signalling probe. The Ag-NCs were synthesized via chemical reduction in the presence of a DNA strand with the sequence of 5'-GCAGTTGATCCTTTGGATACCCTGG-C-12-3'. The strand contains mucin 1 aptamer (GCAGTTGATCCTTTGGATACCCTGG) that can specifically bind to MUC1 and the template (C-12) for synthesis of Ag-NCs. The assay involves the following steps: (1) Construction of an immunosensor by immobilizing the antibody against MUC-1 on a glassy carbon electrode; (2) addition of sample containing MUC-1; (3) addition of Ag-NCs; (4) signal amplification via silver enhancement process (deposition of metal silver on Ag-NCs); (5) measurement via square wave voltammetry. The current measured at a potential of 0.11 V (vs. SCE) is logarithmically related to the concentration of MUC-1 in the 1 to 500 nM range, with a detection limit of 0.5 nM. We also demonstrate that MCF-7 cancer cells can be detected by this method with high sensitivity (50 cells per mL) due to the presence of MUC-1 proteins on the cell surface.