Postoperative changes in in vivo measured friction in total hip joint prosthesis during walking.

Postoperative changes in in vivo measured friction in total hip joint prosthesis during walking.
复制标题

DOI:
10.1371/journal.pone.0120438
复制
发表时间:
2015
期刊:
影响因子:
3.7
通讯作者:
Bergmann G
Bergmann G
中科院分区:
综合性期刊3区
文献类型:
--
作者:
Damm P;Bender A;Bergmann G

文献摘要

参考文献

被引文献

相似文献

Loosening of the artificial cup and inlay is the most common reasons for total hip replacement failures. Polyethylene wear and aseptic loosening are frequent reasons. Furthermore, over the past few decades, the population of patients receiving total hip replacements has become younger and more active. Hence, a higher level of activity may include an increased risk of implant loosening as a result of friction-induced wear. In this study, an instrumented hip implant was used to measure the contact forces and friction moments in vivo during walking. Subsequently, the three-dimensional coefficient of friction in vivo was calculated over the whole gait cycle. Measurements were collected from ten subjects at several time points between three and twelve months postoperative. No significant change in the average resultant contact force was observed between three and twelve months postoperative. In contrast, a significant decrease of up to 47% was observed in the friction moment. The coefficient of friction also decreased over postoperative time on average. These changes may be caused by ‘running-in’ effects of the gliding components or by the improved lubricating properties of the synovia. Because the walking velocity and contact forces were found to be nearly constant during the observed period, the decrease in friction moment suggests an increase in fluid viscosity. The peak values of the contact force individually varied by 32%-44%. The friction moment individually differed much more, by 110%-129% at three and up to 451% at twelve months postoperative. The maximum coefficient of friction showed the highest individual variability, about 100% at three and up to 914% at twelve months after surgery. These individual variations in the friction parameters were most likely due to different ‘running-in’ effects that were influenced by the individual activity levels and synovia properties.
DOI: 10.1016/s0021-9290(00)00188-3
发表时间: 2001-04-01
影响因子: 2.4
作者:
Bergmann, G;Graichen, F;van Lenthe, GH
通讯作者: van Lenthe, GH
DOI: 10.1055/s-2008-1040311
发表时间: 1989-11-01
期刊: ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE
影响因子: --
作者:
BERGMANN, G;ROHLMANN, A;GRAICHEN, F
通讯作者: GRAICHEN, F
DOI: 10.1515/bmte.1994.39.10.251
发表时间: 1994-10-01
期刊: BIOMEDIZINISCHE TECHNIK
影响因子: --
作者:
GRAICHEN, F;BERGMANN, G;ROHLMANN, A
通讯作者: ROHLMANN, A
DOI: 10.1136/ard.2004.033266
发表时间: 2005-12-01
影响因子: 27.4
作者:
Huch, K;Müller, KAC;Günther, KP
通讯作者: Günther, KP
DOI: 10.1080/17453670610013493
发表时间: 2007-02-01
期刊: ACTA ORTHOPAEDICA
影响因子: 3.7
作者:
Flugsrud, Gunnar B.;Nordsletten, Lars;Meyer, Haakon E.
通讯作者: Meyer, Haakon E.