Reproducibility of repeated human regional splenic blood flow measurements using [15O] water and positron emission tomography
Reproducibility of repeated human regional splenic blood flow measurements using [15O] water and positron emission tomography
复制标题
DOI:
10.1097/00006231-200107000-00005
复制
发表时间:
2001-07-01
影响因子:
1.5
通讯作者:
Yamagishi, H
中科院分区:
文献类型:
--
作者:
Taniguchi, H;Kunishima, S;Yamagishi, H
The reproducibility of measurement of regional splenic blood flow by dynamic positron emission tomography (PET) using [O-15]water was evaluated. In 19 patients, the correlation between the first and second of two serial dynamic measurements was significant (P = 1.78 x 10(-6); r = 0.858). The regression equation was y = 1.06x, and the slope of the line described had a 95% confidence interval of 0.09. The error apparent between the two measurements was 0.129 (95% confidence interval 0.059). The results demonstrated sufficiently good reproducibility for measurements of regional splenic blood flow with PET and [O-15]water to suggest use of this method for serial measurements intended to detect change, including drug effects. ((C) 2001 Lippincott Williams & Wilkins).