Reagentless, reusable, ultrasensitive electrochemical molecular beacon aptasensor

Reagentless, reusable, ultrasensitive electrochemical molecular beacon aptasensor
复制标题

DOI:
10.1021/ja053121d
复制
发表时间:
2006-01-11
影响因子:
15
通讯作者:
O'Sullivan, CK
O'Sullivan, CK
中科院分区:
化学1区
文献类型:
--
作者:
Radi, AE;Sánchez, JLA;O'Sullivan, CK

文献摘要

被引文献

相似文献

合成了具有氧化还原活性Fc片段和适体链末端巯基的凝血酶结合适体的双功能衍生物。二茂铁标记的适体硫醇通过S-Au键在多晶金电极表面自组装,表面被2-巯基乙醇阻断,形成混合单层。利用荧光分子信标,确定了反离子对四联体形成的影响。采用循环伏安法(CV)、差分脉冲伏安法(DPV)和电化学阻抗谱(EIS)对配体修饰电极进行了电化学表征。在pH 8.0的10 mM N-(2-羟乙基)哌嗪-N-2-乙磺酸(HEPES)缓冲液中,固定在电极表面的二茂铁基部分发生一步氧化还原反应,显示出伏安信号。2-巯基乙醇阻断后,DPV电流信号明显增加,有效去除非特异性吸收的适配体,而不是结合到电极表面,或者由于适配体-凝血酶亲和相互作用的形成。阻抗测量结果与差分脉冲伏安法(DPV)一致,显示法拉第电阻在相同的顺序上降低。凝血酶结合的“信号开启”可归因于探针修饰膜上的构象从随机线圈状结构改变为四重结构。改性电极的DPV在5.0 ~ 35.0 nM范围内对Fc氧化信号呈线性响应,线性相关r = 0.9988,检出限为0.5 nM。通过在1.0 M HCl中展开适体,分子信标适体传感器可以完全再生,并且在随后的凝血酶结合后可以再生25次而没有电化学信号损失。
A bifunctional derivative of the thrombin-binding aptamer with a redox-active Fc moiety and a thiol group at-the termini of the aptamer strand was synthesized. The ferrocene-labeled aptamer thiol was self-assembled through S-Au bonding on a polycrystalline gold electrode surface and the surface was blocked with 2-mercaptoethanol to form a mixed monolayer. By use of a fluorescent molecular beacon, the effect of counterions on quadruplex formation was established. The aptamer-modified electrode was characterized electrochemically by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). The modified electrode showed a voltammetric signal due to a one-step redox reaction of the surface-confined ferrocenyl moiety of the aptamer immobilized on the electrode surface in 10 mM N-(2-hydroxyethyl) piperazine-N-2-ethanesulfonic acid (HEPES) buffer of pH 8.0. An increase in the DPV current signal was evident after blocking with 2-mercaptoethanol, effectively removing aptamer nonspecifically absorbed rather than bound to electrode surface or due to the formation of the aptamer-thrombin affinity interaction. The impedance measurement, in agreement with the differential pulse voltarnmetry (DPV), showed decreased Faradaic resistances in the same sequence. The "signal-on" upon thrombin association could be attributed to a change in conformation from random coil-like configuration on the probe-modified film to the quadruplex structure. The DPV of the modified electrode showed a linear response of the Fc oxidation signal to the increase in the thrombin concentration in the range between 5.0 and 35.0 nM with a linear correlation of r = 0.9988 and a detection limit of 0.5 nM. The molecular beacon aptasensor was amenable to full regeneration by simply unfolding the aptamer in 1.0 M HCl, and could be regenerated 25 times with no loss in electrochemical signal upon subsequent thrombin binding.