Comparative Study Between Resorbable and Nonresorbable Plates in Orthognathic Surgery
Comparative Study Between Resorbable and Nonresorbable Plates in Orthognathic Surgery
复制标题
DOI:
10.1016/j.joms.2009.07.020
复制
发表时间:
2010-02-01
影响因子:
1.9
通讯作者:
Son, Jun-Sik
中科院分区:
文献类型:
--
作者:
Ahn, Yu-Seok;Kim, Su-Gwan;Son, Jun-Sik
Purpose: The purpose of the present study was to evaluate the clinical application of resorbable and nonresorbable plates for correction of facial asymmetry.Patients and Methods: A total of 272 patients who had undergone orthognathic surgery were enrolled. The site of osteotomy was fixed using a nonresorbable plate in group 1 (n = 152) and using a resorbable plate in group 11(n = 120). The postoperative complications included postoperative anterior open bite, infection, temporomandibular joint dysfunction, and postoperative relapse. The incidence of all complications was examined.Results: The surgical outcome was successful in 269 patients (98.89%). Of the 152 patients with a titanium plate, 13 (8.6%) developed complications. Of the 120 patients with a resorbable plate, 22 (18.3%) developed complications. A greater degree of postoperative open bite and a trend toward relapse were observed in patients' cases in which an absorbable fixation plate was used. Postoperative infection occurred in patients with an absorbable fixation plate.Conclusion: On the basis of these data, we have concluded that an absorbable fixation plate should be used instead of a titanium fixation plate in indicated patients. Crown Copyright (C) 2010 Published by Elsevier Inc on behalf of American Association of Oral and Maxillofacial Surgeons. All rights reserved. J Oral Mayillofac Surg 68:287-292, 2010