Stented elephant trunk procedure for an extensive aneurysm involving distal aortic arch and descending aorta

Stented elephant trunk procedure for an extensive aneurysm involving distal aortic arch and descending aorta
复制标题

DOI:
10.1016/s0022-5223(96)70157-5
复制
发表时间:
1996-11-01
影响因子:
6
通讯作者:
Sakuma, M
Sakuma, M
中科院分区:
医学1区
文献类型:
--
作者:
Suto, Y;Yasuda, K;Sakuma, M

文献摘要

被引文献

相似文献

讨论自从 Borst、Walterbusch 和 Schaps 1 于 1983 年推出象鼻技术以来,该技术已广泛用于分期主动脉置换术。 2, 3, 4 此外,这些调查人员报告了一例,长象鼻周围的死腔充满了凝块,不需要进一步手术。 2 作者强调这种现象是该技术的进一步潜在用途。 Crawford 及其同事 3 报告了该方法的并发症:移植物扭结和闭塞、移植物周围凝块导致的截瘫以及拍打动作引起的外周血栓栓塞。他们表示,当躯干较长时,这些并发症的可能性更大。
DiscussionSince Borst, Walterbusch, and Schaps 1 introduced the elephant trunk technique in 1983 this technique has been widely used for staged aortic replacement. 2, 3, 4 In addition, these investigators reported one case in which the dead space around the long elephant trunk was filled with clot and further operation was not needed. 2 The authors highlighted this phenomenon as a further potential use of this technique. Crawford and associates 3 reported complications of this method: kinking and occlusion of the graft, paraplegia as a result of clot around the graft, and peripheral thromboembolism caused by flapping action. They stated that these complications were more likely when the trunk was longer.