Chemiluminescence of carbon dots induced by diperiodato-nicklate (IV) in alkaline solution and its application to a quenchometric flow-injection assays of paracetamol, L-cysteine and glutathione

Chemiluminescence of carbon dots induced by diperiodato-nicklate (IV) in alkaline solution and its application to a quenchometric flow-injection assays of paracetamol, L-cysteine and glutathione
复制标题

DOI:
10.1007/s00604-014-1427-y
复制
发表时间:
2015-04-01
期刊:
影响因子:
5.7
通讯作者:
Sun, Hanwen
Sun, Hanwen
中科院分区:
化学2区
文献类型:
--
作者:
Dong, Yajuan;Su, Ming;Sun, Hanwen

文献摘要

被引文献

相似文献

采用微波辅助热碳化法制备了碳量子点水溶液。用透射电镜、吸收光谱和荧光光谱对它们进行了研究。研究了强氧化剂二过碘酸镍(IV)在强碱性溶液中诱导C点化学发光的机理。提出了该反应的机理。对乙酰氨基酚、L-半胱氨酸和谷胱甘肽对体系的化学发光有猝灭作用。在优化条件下,校准曲线呈线性,相关系数(r)> 0.995。对乙酰氨基酚、L-半胱氨酸和谷胱甘肽的检测限分别为90、8和60 A μ g L-1。分析加标尿液和血清样品,回收率在84.38%-116.0%范围内,RSD为1.2%-2.7%。
Aqueous solutions of carbon dots (C-dots) were prepared by microwave-assisted thermal carbonization of poly(ethylene glycol). They were investigated by transmission electron microscopy, absorption and fluorescence spectra. It is shown that diperiodato-nicklate(IV), a strong oxidant, induces the chemiluminescence (CL) of C-dots in strongly alkaline solution without use of an additional reagent. A mechanism for this reaction is suggested. It is also found that the CL of the system is quenched by paracetamol, L-cysteine and glutathione. Under the optimized conditions, the calibration plot is linear with a correlation coefficient (r) of > 0.995. The limits of detection are 90, 8, and 60 A mu g L-(1) for paracetamol, L-cysteine, and glutathione, respectively. Spiked urine and serum samples were analyzed and gave recoveries in the range from 84.38 to 116.0 %, with an RSD of 1.2-2.7 %.