Early trans-tibial oedema control using polymer gel socks
Early trans-tibial oedema control using polymer gel socks
复制标题
DOI:
10.1080/03093640308726685
复制
发表时间:
2003-12-01
影响因子:
1.5
通讯作者:
Freijah, N
中科院分区:
文献类型:
--
作者:
Graf, M;Freijah, N
The aim of this investigation was to determine if early trans-tibial oedema control, by polymer gel socks prior to the fitting of a shrinker, could enhance trans-tibial stump volume reduction.Sixteen (16) adults, following unilateral transtibial amputation, were randomly allocated into 2 groups and baseline volume measurements taken of their stumps. The control group followed the normal removable rigid dressing programme, while the experimental group wore a polymer gel sock in conjunction with the removable rigid dressing.When wound healing permitted fitting of a shrinker, use of the polymer sock was discontinued and a stump volume measurement was taken. The shrinker was worn for a minimum of 2 days before casting for a prosthesis and a final stump volume measurement taken.Volumes were measured by water filling casts taken of the stump and calculated as a percentage of the baseline volume and the rate of volume reduction calculated.Two t-tests for unequal variance (2-tail, alpha=0.05) were used to compare the rate of percentage volume reduction between the groups, for the trial period of baseline to shrinker fitting and baseline to casting. A statistical difference was observed for the period of baseline to shrinker exceeding the 95% confidence limit (p