Partial discharge testing of defects in dielectric insulation under DC and voltage ripple conditions
Partial discharge testing of defects in dielectric insulation under DC and voltage ripple conditions
复制标题
直流和电压纹波条件下介电绝缘缺陷的局部放电测试
DOI:
--
复制
发表时间:
2018
期刊:
影响因子:
--
通讯作者:
R. Giussani
中科院分区:
文献类型:
--
作者:
E. Corr;A. Reid;Xiao Hu;W. H. Siew;M. Zhu;M. Judd;M. Seltzer;R. Giussani
This paper details testing conducted on selected void defects in dielectric insulation
samples under various HVDC voltage conditions. The aim of this work is to illustrate the type of PD
activity that could be observed in HVDC insulation systems. Initially the samples were subject to
HVAC excitation to confirm the defect type and establish the PD inception voltage. HVDC testing was
then conducted using a ‘ramp and hold’ test technique with different hold voltages in the ramp
determined from the measured HVAC inception voltage. The effect of harmonic ripple superimposed
on the HVDC voltage waveform, which is typically a result of the converter switching operation, was
also investigated. The findings from this study should provide network operators and insulation
manufacturers a greater insight into the behavior of PD phenomena in solid insulation under HVDC
conditions, enabling greater confidence in the diagnosis of defect type and severity in such systems.