Ultrasonography of the Anterior Segment.
Ultrasonography of the Anterior Segment.
复制标题
眼前段超声检查。
DOI:
10.1016/j.cult.2008.04.004
复制
发表时间:
2008
期刊:
影响因子:
--
通讯作者:
Jeng,BennieH
中科院分区:
文献类型:
--
作者:
Heur,Martin;Jeng,BennieH
Most of the anterior segment structures can be evaluated with slit lamp biomicroscopy because of corneal transparency. The cornea is the main refractive element of the eye, accounting for two-thirds of the total refractive power. Because of this function, there are many mechanisms through which the cornea maintains its transparency, including ultrastructural arrangement of its collagen lamellae, maintenance of avascularity, and endothelial pump function for deturgesence. The cornea is routinely examined by slit lamp biomicroscopy because of its transparency, and therefore it is not routinely evaluated with ultrasound. However, there are some situations in which the cornea loses its transparency, and the ultrasound becomes an important adjunct in the evaluation of the anterior segment. In situations requiring ultrasound evaluation of the anterior segment, because of the limitations of B-scan ultrasonography, ultrasound biomicroscopy (UBM), due to its high resolution, is the preferred modality. 1 This chapter will review UBM evaluation of the cornea, intraocular lenses, and anterior segment trauma.