Design of Ultra-Fast Charge eXchange Recombination Spectroscopy diagnostic on EAST tokamak
Design of Ultra-Fast Charge eXchange Recombination Spectroscopy diagnostic on EAST tokamak
复制标题
DOI:
10.1088/1748-0221/12/08/c08022
复制
发表时间:
2017-08
影响因子:
1.3
通讯作者:
Y. Yu;Y. Li;M. Ye;H. Wang;Z. Chen;Y. Wu;S. Mao;B. Lyu;B. Wan;East Team
中科院分区:
文献类型:
--
作者:
Y. Yu;Y. Li;M. Ye;H. Wang;Z. Chen;Y. Wu;S. Mao;B. Lyu;B. Wan;East Team
In this article, we present the design of a four-channel Ultra-Fast Charge eXchange Recombination Spectroscopy (UF-CXRS) diagnostic on the EAST tokamak. This diagnostic is based on the active charge exchange to measure ion temperature with a time resolution at the order of 1 μ s and a spatial resolution of 1 cm. The design of the main components is carefully discussed, including the dichroic mirror light path, the fiber, the spectrometer and the customized lens. The theoretical estimation of the emission photon flux has been carried out, proving the feasibility of the whole design.