Improved Hold-Up Time for WBG-based Single-Phase Converters

Improved Hold-Up Time for WBG-based Single-Phase Converters
复制标题

DOI:
10.23919/epe.2019.8914818
复制
发表时间:
2019-09
期刊:
2019 21st European Conference on Power Electronics and Applications (EPE '19 ECCE Europe)
影响因子:
--
通讯作者:
Rajesh Rajamony;Wenlong Ming
Rajesh Rajamony;Wenlong Ming
中科院分区:
其他
文献类型:
--
作者:
Rajesh Rajamony;Wenlong Ming

文献摘要

相似文献

电源转换器的安全、不间断运行需要保持时间。这可以防止不必要的系统重置。本文研究了具有显著减小的直流电容的单相变换器的保持时间。选择所需的断开电容和辅助电容,以确保在输入电源故障后保持一定的时间。为了最大限度地利用脱链电压,本文提出了一种简化的中性点支路控制策略,保证了在保持状态下变流器的控制。提出了一种权衡设计策略,并与不加辅助电容的方案进行了比较。仿真研究验证了变换器的保持时间性能。
Hold-up time is required for the safe and uninterrupted operation of the power converters. This prevents unwanted resetting of the systems. In this paper, the hold-up time for a single-phase converter with siginificantly-reduced DC capacitors is investigated. The required de-link and auxiliary capacitors are selected to ensure a certain period of hold-up time after the input supply fails. To maximize the utilization of de-link voltage, this paper presents a simplified neutral leg control strategy and it has been ensured the converter control under hold-up operations. A trade-off design strategy is presented and the outcome has been compared with the solution without the auxiliary capacitor. Simulation studies were carried out to verify the hold-up time performance of the converters.