Multi-strip MRPCs for FOPI
Multi-strip MRPCs for FOPI
复制标题
DOI:
10.1016/j.nima.2008.12.088
复制
发表时间:
2009-05
影响因子:
1.4
通讯作者:
A. Schüttauf;M. Ciobanu;K. Hildenbrand;M. Kis;I. Deppner;N. Herrmann;Yongsung Kim;T. I. Kang;P. Koczoń;X. Lopez;Y. Leifels;M. Petrovici;K. Piasecki;A. Reischl;W. Reisdorf;M. Ryu;V. Simion;N. Zernezki;X. Zhang
中科院分区:
文献类型:
--
作者:
A. Schüttauf;M. Ciobanu;K. Hildenbrand;M. Kis;I. Deppner;N. Herrmann;Yongsung Kim;T. I. Kang;P. Koczoń;X. Lopez;Y. Leifels;M. Petrovici;K. Piasecki;A. Reischl;W. Reisdorf;M. Ryu;V. Simion;N. Zernezki;X. Zhang
During the last years FOPI has developed a new ToF system as an upgrade of the existing detector based on Multi-strip Multi-gap Resistive Plate Chambers (MMRPCs). The intention is to increase the charged Kaon identification up to a laboratory momentum of 1GeV/c and to enhance the azimuthal detector granularity. The new ToF barrel has an active area of 5m2with 2400 individual strips (900×1.6mm2) [A. Schüttauf, et al., Nucl. Phys. B 158 (2006) 52] which are read out on both sides by a custom designed electronics [M. Ciobanu, et al., IEEE Trans. Nucl. Sci. NS-54 (4) (2007) 1201; K. Koch, et al., IEEE Trans. Nucl. Sci. NS-52(3) (2005) 745]. To reach the envisaged goal a time resolution of 100ps is needed, at a flight path of 1–1.3m. Due to the rare production of the K−at SIS energies the efficiency of the MMRPCs has to be above 95%. We report on measurements with the detectors and electronics from the mass production line. For this purpose we used a proton beam at 2.0 and 1.25GeV, at rates between 0.1 and 5kHz/cm2to determine the timing, efficiency and rate capability of the MMRPCs.