Tissue specific considerations in implementing high intensity focussed ultrasound under magnetic resonance imaging guidance.

Tissue specific considerations in implementing high intensity focussed ultrasound under magnetic resonance imaging guidance.
复制标题

DOI:
10.3389/fonc.2022.1037959
复制
发表时间:
2022
影响因子:
4.7
通讯作者:
Ter Haar G
Ter Haar G
中科院分区:
医学3区
文献类型:
--
作者:
deSouza NM;Gedroyc W;Rivens I;Ter Haar G

文献摘要

参考文献

被引文献

相似文献

High-intensity focused ultrasound can ablate a target permanently, leaving tissues through which it passes thermally unaffected. When delivered under magnetic resonance (MR) imaging guidance, the change in tissue relaxivity on heating is used to monitor the temperatures achieved. Different tissue types in the pre-focal beam path result in energy loss defined by their individual attenuation coefficients. Furthermore, at interfaces with different acoustic impedances the beam will be both reflected and refracted, changing the position of the focus. For complex interfaces this effect is exacerbated. Moreover, blood vessels proximal to the focal region can dissipate heat, altering the expected region of damage. In the target volume, the temperature distribution depends on the thermal conductivity (or diffusivity) of the tissue and its heat capacity. These are different for vascular tissues, water and fat containing tissues and bone. Therefore, documenting the characteristics of the pre-focal and target tissues is critical for effective delivery of HIFU. MR imaging provides excellent anatomic detail and characterization of soft tissue components. It is an ideal modality for real-time planning and monitoring of HIFU ablation, and provides non-invasive temperature maps. Clinical applications involve soft-tissue (abdomino-pelvic applications) or bone (brain applications) pre-focally and at the target (soft-tissue tumors and bone metastases respectively). This article addresses the technical difficulties of delivering HIFU effectively when vascular tissues, densely cellular tissues, fat or bone are traversed pre-focally, and the clinical applications that target these tissues. The strengths and limitations of MR techniques used for monitoring ablation in these tissues are also discussed.
DOI: 10.1056/nejmoa1300962
发表时间: 2013-08-15
影响因子: 158.5
作者:
Elias, W. Jeffrey;Huss, Diane;Wintermark, Max
通讯作者: Wintermark, Max
DOI: 10.1093/bja/aev302
发表时间: 2015-10-01
影响因子: 9.8
作者:
Brown, M. R. D.;Farquhar-Smith, P.;deSouza, N. M.
通讯作者: deSouza, N. M.
DOI: 10.3892/ol.2020.11511
发表时间: 2020-06-01
期刊: ONCOLOGY LETTERS
影响因子: 2.9
作者:
Guo, Xiaoyin;Zhu, Hui;Dimitrov, Dobromir Dimitrov
通讯作者: Dimitrov, Dobromir Dimitrov
DOI: 10.1148/rg.2018170129
发表时间: 2018-03-01
期刊: RADIOGRAPHICS
影响因子: 5.5
作者:
Dababou, Susan;Marrocchio, Cristina;Napoli, Alessandro
通讯作者: Napoli, Alessandro
DOI: 10.1186/2050-5736-217
发表时间: 2014-01-01
期刊: JOURNAL OF THERAPEUTIC ULTRASOUND
影响因子: --
作者:
Coluccial, Daniel;Fandino, Javier;Werner, Beat
通讯作者: Werner, Beat