Novel TrueVue series of 3D echocardiography: Revealing the pathological morphology of congenital heart disease.

Novel TrueVue series of 3D echocardiography: Revealing the pathological morphology of congenital heart disease.
复制标题

新型TrueVue系列3D超声心动图:揭示先天性心脏病的病理形态

DOI:
10.3389/fphys.2022.1000007
复制
发表时间:
2022
影响因子:
4
通讯作者:
--
中科院分区:
医学2区
文献类型:
--
作者:

文献摘要

参考文献

被引文献

相似文献

目的:本文探讨了三维超声心动图技术的优点和局限性,并总结了其在先天性心脏病中的应用方法。 方法和结果:对62例冠心病患者进行二维(2D)、传统3D超声心动图和TrueVue plus light和/或Glass新型3D技术检查,并设计临床调查以判断新型3D图像是否比传统3D图像更有助于了解心脏状况和指导治疗。TrueVue提高了视觉分辨率,模拟了心脏组织的真实纹理,显著提高了CHD异常解剖结构的显示能力。TrueVue Glass更直观地显示了心腔的血流通道和内部结构,显示了传统超声心动图所没有的新的观察视角。临床调查结果表明,新的3D成像方法有效地增加了超声心动图医师的诊断信心,使外科医生更好地了解病变的细节,促进了高效的沟通,提高了医患双方治疗的信心。 结论:TrueVue、TrueVue Light和TrueVue Glass的联合应用较传统影像技术更接近模拟真实的解剖特征,显示管腔内更全面、更细微的血流,不仅增加了视觉效果,而且提供了更有用的诊断信息,提高了冠心病评估和治疗的准确性,表明该联合应用具有重要的临床价值。
Aims: This study explored the advantages and limitations of novel series of three-dimensional (3D) echocardiographic techniques and summarized their application methods for congenital heart diseases (CHDs). Method and result: Two-dimensional (2D), traditional 3D echocardiography, and TrueVue plus light and/or Glass novel 3D technologies were performed on 62 patients with CHD, and a clinical survey was designed to judge whether the novel 3D images were more helpful for understanding the cardiac condition and guide treatment than traditional 3D images. TrueVue increased the visual resolution and simulated the true texture of cardiac tissue, significantly improving the display ability of abnormal anatomical structures in CHDs. TrueVue Glass displayed the blood channel and the internal structure of cardiac cavity more intuitively, indicating a new observation aspect not shown by conventional echocardiography. The clinical survey results showed that the new 3D imaging methods effectively increased the diagnostic confidence of echocardiographers, enabled surgeons to better understand the details of lesions, promoted efficient communication, and improved the confidence of both doctors and patients in treatment. Conclusion: The combined application of TrueVue, TrueVue Light, and TrueVue Glass more closely simulated real anatomical features, showed more comprehensive and subtle blood flow in the lumen, not only increased the visual effect but also provided more useful diagnostic information, improved the accuracy of evaluation and treatment of CHD when compared to traditional imaging techniques, indicating that this combined application has significant clinical value.
DOI: 10.1016/j.echo.2020.06.016
发表时间: 2020-11-01
影响因子: 6.5
作者:
Harake, Danielle;Gnanappa, Ganesh Kumar;Khoo, Nee Scze
通讯作者: Khoo, Nee Scze
DOI: 10.1016/j.echo.2010.08.008
发表时间: 2010-11-01
影响因子: 6.5
作者:
Saric, Muhamed;Perk, Gila;Kronzon, Itzhak
通讯作者: Kronzon, Itzhak
DOI: 10.1080/14767058.2019.1702949
发表时间: 2019-12-27
影响因子: 1.8
作者:
Sehgal, Arvind;Nitzan, Itamar;Tan, Kenneth
通讯作者: Tan, Kenneth
DOI: 10.1161/circimaging.114.002502
发表时间: 2014-11-01
影响因子: 7.5
作者:
Charakida, Marietta;Pushparajah, Kuberan;Simpson, John M.
通讯作者: Simpson, John M.
DOI: 10.1016/j.ijcard.2005.09.012
发表时间: 2006-09-20
影响因子: 3.5
作者:
van den Bosch, Annemien E.;Ten Harkel, Derk-Jan;Meijboom, Folkert J.
通讯作者: Meijboom, Folkert J.