Experimental study on the effect of neutron shielding material on radioisotope backscattering detector
Experimental study on the effect of neutron shielding material on radioisotope backscattering detector
复制标题
中子屏蔽材料对放射性同位素背散射探测器影响的实验研究
DOI:
10.11532/structcivil.68a.825
复制
发表时间:
2022
期刊:
影响因子:
--
通讯作者:
池永 太一
中科院分区:
文献类型:
--
作者:
神頭 峰磯;瀬古 繁喜;池永 太一
To find voids in concrete, when we used a radioisotope backscatter detector, the thermal neutron measurement results included the effect from the sides of the detector in our prior studies. This is caused by scattered fast neutron in all directions from the source. To solve this problem, two types of experiments were conducted. In the first, the characteristics of different moderators were investigated to choose the applicable material. In the second, when the moderator was attached to the void detecting system, movement of radio-isotope count on mock specimen were examined experimentally. The experiments in this paper revealed that attached moderator to this device improves the void detection capability.