Performance of the MRI-based virtual bone biopsy in the distal radius: serial reproducibility and reliability of structural and mechanical parameters in women representative of osteoporosis study populations.
Performance of the MRI-based virtual bone biopsy in the distal radius: serial reproducibility and reliability of structural and mechanical parameters in women representative of osteoporosis study populations.
复制标题
DOI:
10.1016/j.bone.2011.07.010
复制
发表时间:
2011-10
期刊:
影响因子:
4.1
通讯作者:
Wehrli, Felix W.
中科院分区:
文献类型:
--
作者:
Lam, Shing Chun Benny;Wald, Michael J.;Rajapakse, Chamith S.;Liu, Yinxiao;Saha, Punam K.;Wehrli, Felix W.
Serial reproducibility and reliability critically determine sensitivity to detect changes in response to intervention and provide a basis for sample size estimates. Here, we evaluated the performance of the MRI-based Virtual Bone Biopsy in terms of 26 structural and mechanical parameters in the distal radius of 20 women in the age range of 50 to 75 years (mean = 62.0 years, S.D. = 8.1 years), representative of typical study populations in drug intervention trials and fracture studies. Subjects were examined three times at average intervals of 20.2 days (S.D. = 14.5 days) by MRI at 1.5 T field strength at a voxel size of 137×137×410 μm3. Methods involved prospective and retrospective 3D image registration and auto-focus motion correction. Analyses were performed from a central 5×5×5 mm3 cuboid subvolume and trabecular volume consisting of a 13 mm axial slab encompassing the entire medullary cavity. Whole-volume axial stiffness and sub-regional Young’s and shear moduli were computed by finite-element analysis. Whole-volume-derived aggregate mean coefficient of variation of all structural parameters was 4.4% (range 1.8% to 7.7%) and 4.0% for axial stiffness; corresponding data in the subvolume were 6.5% (range 1.6% to 13.0%) for structural, and 5.5% (range 4.6% to 6.5%) for mechanical parameters. Aggregate ICC was 0.976 (range 0.947 to 0.986) and 0.992 for whole-volume-derived structural parameters and axial stiffness, and 0.946 (range 0.752 to 0.991) and 0.974 (range 0.965 to 0.978) for subvolume-derived structural and mechanical parameters, respectively. The strongest predictors of whole-volume axial stiffness were BV/TV, junction density, skeleton density and Tb.N (R2 0.79 – 0.87). The same parameters were also highly predictive of sub-regional axial modulus (R2 0.88 – 0.91). The data suggest that the method is suited for longitudinal assessment of the response to therapy. The underlying technology is portable and should be compatible with all general-purpose MRI scanners, which is appealing considering the very large installed base of this modality.
登录
查看更多内容
影响因子:
6.2
作者:
Boutroy, Stephanie;Van Rietbergen, Bert;Delmas, Pierre D.
通讯作者:
Delmas, Pierre D.
影响因子:
6.2
作者:
Ladinsky, Glenn A.;Vasilic, Branimir;Wehrli, Felix W.
通讯作者:
Wehrli, Felix W.
影响因子:
4.5
作者:
HARRIGAN, TP;MANN, RW
通讯作者:
MANN, RW
影响因子:
3.3
作者:
Hwang, SN;Wehrli, FW
通讯作者:
Wehrli, FW
影响因子:
3.8
作者:
Li, Charles Q.;Magland, Jeremy F.;Wehrli, Felix W.
通讯作者:
Wehrli, Felix W.