CFD research on runaway transient of pumped storage power station caused by pumping power failure
CFD research on runaway transient of pumped storage power station caused by pumping power failure
复制标题
DOI:
10.1088/1757-899x/52/5/052027
复制
发表时间:
2013-12
期刊:
影响因子:
--
通讯作者:
L. G. Zhang;D. Zhou
中科院分区:
文献类型:
--
作者:
L. G. Zhang;D. Zhou
To study runaway transient of pumped storage power station caused by pumping power failure, three dimensional unsteady numerical simulations were executed on geometrical model of the whole flow system. Through numerical calculation, the changeable flow configuration and variation law of some parameters such as unit rotate speed,flow rate and static pressure of measurement points were obtained and compared with experimental data. Numerical results show that runaway speed agrees well with experimental date and its error was 3.7%. The unit undergoes pump condition, brake condition, turbine condition and runaway condition with flow characteristic changing violently. In runaway condition, static pressure in passage pulses very strongly which frequency is related to runaway speed.