COMPARISON OF STATIC AND DYNAMIC CEREBRAL AUTOREGULATION MEASUREMENTS
COMPARISON OF STATIC AND DYNAMIC CEREBRAL AUTOREGULATION MEASUREMENTS
复制标题
DOI:
10.1161/01.str.26.6.1014
复制
发表时间:
1995-06-01
期刊:
影响因子:
8.3
通讯作者:
NEWELL, DW
中科院分区:
文献类型:
--
作者:
TIECKS, FP;LAM, AM;NEWELL, DW
Background mid Purpose Cerebral autoregulation can be evaluated by measuring relative blood flow changes in response to a steady-state change in the blood pressure (static method) or during the response to a rapid change in blood pressure (dynamic method). The purpose of this study was to compare the results of the two methods in humans with both intact and impaired autoregulatory capacity.Methods Using intraoperative transcranial Doppler sonography recordings from both middle cerebral arteries, we determined static and dynamic autoregulatory responses in 10 normal subjects undergoing elective surgical procedures. The changes in cerebrovascular resistance were estimated from the changes in cerebral blood flow velocity and arterial blood pressure in response to manipulations of blood pressure. Static autoregulation was determined by analyzing the response to a phenylephrine-induced rise in blood pressure, whereas rapid deflation of a blood pressure cuff around one thigh served as a stimulus for testing dynamic autoregulation. Both measurements were performed in patients with intact autoregulation during propofol anesthesia and again in the same patients after autoregulation had been impaired by administration of high-dose isoflurane.Results There was a significant reduction in autoregulatory capacity after the administration of high-dose isoflurane, which could be demonstrated using static (P