Detection of brain metastasis at 3T: comparison among SE, IR-FSE and 3D-GRE sequences
Detection of brain metastasis at 3T: comparison among SE, IR-FSE and 3D-GRE sequences
复制标题
DOI:
10.1007/s00330-007-0599-9
复制
发表时间:
2007-09-01
影响因子:
5.9
通讯作者:
Kitajima, Mika
中科院分区:
文献类型:
--
作者:
Kakeda, Shingo;Korogi, Yukunori;Kitajima, Mika
The objective of this study is to compare the detectability of brain metastases at 3T among three contrast-enhanced sequences, spin-echo (SE) sequence, inversion recovery fast SE (IR-FSE) sequence (both with section thickness of 6 mm), and three-dimensional fast spoiled gradient-echo (3D fast SPGR) sequence with 1.4 mm isotropic voxel. First, phantom studies were performed to quantify the contrast-enhancement ratio (CER) with three sequences. In 21 consecutive patients with brain metastases, axial images of three sequences at 3T were obtained after administration of gadoteridol. Two neuroradiologists assessed the detectability of brain metastases for the three sequences. In the phantom study, no evident difference in the CER was demonstrated among three sequences. Significantly more brain metastases were detected with 3D fast SPGR than with SE and IR-FSE (a total of 97 lesions with 3D fast SPGR vs. 64 with SE and 63 with IR-FSE). In particular, 3D fast SPGR was superior to the other two sequences in detection of the small lesions (