Simultaneous in-situ determination of U-Pb age and trace elements in zircon by LA-ICP-MS in 20 μm spot size
Simultaneous in-situ determination of U-Pb age and trace elements in zircon by LA-ICP-MS in 20 μm spot size
复制标题
DOI:
10.1007/s11434-007-0160-x
复制
发表时间:
2007
影响因子:
--
通讯作者:
Xiaoming Liu;Shan Gao;Chunrong Diwu;Honglin Yuan;Zhaochu Hu
中科院分区:
文献类型:
--
作者:
Xiaoming Liu;Shan Gao;Chunrong Diwu;Honglin Yuan;Zhaochu Hu
Simultaneousin-situdetermination of U-Pb ages and 20 trace elements of three international zircon standards (91500, GJ1 and TEMORA 1) and one laboratory zircon standard (SK10-2) separated from Cenozoic fine-grained gabbro was carried out on quadrupole ICP-MS equipped with 193 nm excimer laser in 20 μm spot size. The weighted mean206Pb/238U ages of 91500, GJ1 and TEMORA 1 are 1064.4±4.8 Ma (2σ), 603.2±2.4 Ma (2σ) and 418.2±2.4 Ma (2σ), respectively. The relative standard deviations (RSDs) of206Pb/238U ages (2σ) are less than 2.2% for single measurements and 0.6% for weighted means. The obtained weighted mean206Pb/238U ages of three standard zircons agree with the recommended values within 2σ error. The weighted mean206Pb/238U age of SK10-2 is 31.42±0.25 Ma (2σ) and the RSDs of206Pb/238U ages (2σ) are between 2.4% and 5.7% for single measurements and less than 0.8% for weighted mean. The obtained weighted mean206Pb/238U age is in good agreement with the age obtained by Yuan (2004). Trace element concentrations of NIST612 and NIST614 obtained under the same LA-ICP-MS operating conditions agree with the recommended values within analytical error. The results indicate that it is possible to measure U-Pb age and trace elements simultaneously by LA-ICP-MS in a small spot size of 20 μm.