Preventive measures to reduce bird related power outages-part II: streamers and contamination

Preventive measures to reduce bird related power outages-part II: streamers and contamination
复制标题

减少鸟类相关停电的预防措施第二部分:彩带和污染

DOI:
10.1109/tpwrd.2003.822522
复制
发表时间:
2004
影响因子:
4.4
通讯作者:
J. Varner
J. Varner
中科院分区:
工程技术2区
文献类型:
--
作者:
R. Sundararajan;J. Burnham;R. Carlton;E. Cherney;G. Couret;K.T. Eldridge;M. Farzaneh;S. Frazier;R. Harness;D. Shaffner;S. Siegel;J. Varner

文献摘要

被引文献

相似文献

与鸟类有关的停电比通常认为的更常见和更广泛。本文的目的是审查现有的鸟类有关的问题,并建议的做法和程序,成功地减少鸟类有关的停电输电线路,变电站和架空配电线路。经验表明,使用栖木保护装置、金属或塑料长钉、绝缘帽、替代栖木位置和清洗,可以显著减少与鸟类有关的拖缆和污染中断。
Bird related outages are more common and widespread than generally believed. The objective of this paper is to review the existing bird related problems and to recommend practices and procedures that are successful in reducing bird related outages on transmission lines, in substations and on overhead distribution lines. Experience has shown that use of perch guards, metal or plastic spikes, insulating caps, alternate perch sites and washing have significantly reduced bird related streamer and contamination outages.