Schirmer tear test I in dogs: results comparing placement in the ventral vs. dorsal conjunctival fornix.

Schirmer tear test I in dogs: results comparing placement in the ventral vs. dorsal conjunctival fornix.
复制标题

犬泪液分泌试验 I:比较腹侧和背侧结膜穹窿位置的结果。

DOI:
10.1111/vop.12462
复制
发表时间:
2017
影响因子:
1.6
通讯作者:
Whitley,RDavid
Whitley,RDavid
中科院分区:
农林科学3区
文献类型:
--
作者:
Visser,HannahE;Tofflemire,KyleL;Love-Myers,KimR;Allbaugh,RachelA;Ellinwood,NMatthew;Dees,DDustin;Ben-Shlomo,Gil;Whitley,RDavid

文献摘要

相似文献

ObjectiveTo compare Schirmer tear test I (STT I) values obtained from placement of tear strips in the ventral and dorsal conjunctival fornices in dogs.ProcedureSchirmer tear test I was performed on each eye of 16 clinically normal dogs (32 eyes) in a crossover study. Initial tear strip placement site was randomized for each eye. Alternative placement site measurements were obtained after 1 week.ResultsThe mean (± standard deviation, SD) STT I for dorsal and ventral conjunctival fornices was 20.44 (±4.46) mm/min and 23.56 (±3.98) mm/min, respectively. STT I values obtained from the ventral conjunctival fornix were significantly greater than those obtained from the dorsal conjunctival fornix (P= 0.004).ConclusionsSchirmer tear test I values were significantly greater with tear strips placed in the ventral conjunctival fornix.