Measurement of pH Distribution near the Air-cathode of a Single-chamber Microbial Fuel Cell Using Location Sensor-equipped Microelectrodes
Measurement of pH Distribution near the Air-cathode of a Single-chamber Microbial Fuel Cell Using Location Sensor-equipped Microelectrodes
复制标题
使用配备位置传感器的微电极测量单室微生物燃料电池空气阴极附近的 pH 分布
DOI:
10.1016/j.elecom.2016.08.022
复制
发表时间:
2016
影响因子:
5.4
通讯作者:
O. Ichihashi and K. Hirooka
中科院分区:
文献类型:
--
作者:
A. Motoyama;O. Ichihashi and K. Hirooka
The oxygen reduction reaction at the cathode of a microbial fuel cell is known to be responsible for a localized increase in pH, but it is difficult to determine the precise distance between the measurement points and the cathode. In this study, a location sensor was attached to a micro pH electrode to determine this distance during the measurement of pH distribution. Without substrate, the pH slightly increased within the range of 0 to 0.8 mm from the cathode and reached a maximum of 7.2, whereas with substrate, the pH sharply increased within the range of 0 to 1.4 mm and reached 9.3.