Protection of the ocular surface after keratoprosthesis surgery: the role of soft contact lenses.

Protection of the ocular surface after keratoprosthesis surgery: the role of soft contact lenses.
复制标题

角膜假体手术后眼表的保护:软性隐形眼镜的作用。

DOI:
--
复制
发表时间:
2002
期刊:
The CLAO Journal
影响因子:
--
通讯作者:
Sheri Morneault
Sheri Morneault
中科院分区:
--
文献类型:
--
作者:
C. Dohlman;Eric J. Dudenhoefer;B. Khan;Sheri Morneault

文献摘要

被引文献

相似文献

目的 目的探讨软性角膜接触镜在人工角膜术后的短期疗效。 方法 对19例戴领扣形人工角膜的患者进行了软性接触透镜的配戴,并评价了对周围角膜的保护作用。 结果 研究发现,该镜片对器械周围角膜表面的蒸发性损伤具有高度保护作用。它们的耐受性良好,可以保持清洁并保持数月。发生了一次感染。 结论 软性接触透镜对人工角膜周围的角膜具有相当大的保护价值。
PURPOSE To evaluate the short-term therapeutic value of soft contact lenses in patients with keratoprosthesis. METHODS Nineteen patients with a collar button-shaped keratoprosthesis were fitted with a soft contract lens and evaluated for the protective effect on the surrounding cornea. RESULTS The lenses were found to be highly protective against evaporative damage to the corneal surface around the device. They were well tolerated and could remain clean and in place for months. One infection occurred. CONCLUSION A soft contact lens can be of considerable protective value to the cornea surrounding a keratoprosthesis.