Dependence of radiomic features on pixel size affects the diagnostic performance of radiomic signature for the invasiveness of pulmonary ground-glass nodule
Dependence of radiomic features on pixel size affects the diagnostic performance of radiomic signature for the invasiveness of pulmonary ground-glass nodule
复制标题
放射组学特征对像素大小的依赖性影响肺部毛玻璃结节侵袭性放射组学特征的诊断性能
DOI:
10.1259/bjr.20200089
复制
发表时间:
2021-01-01
影响因子:
2.6
通讯作者:
Yu, Hong
中科院分区:
文献类型:
--
作者:
Tao, Guangyu;Yin, Lekang;Yu, Hong
Objective: To investigate the effect of reducing pixel size on the consistency of radiomic features and the diagnostic performance of the downstream radiomic signatures for the invasiveness for pulmonary ground-glass nodules (GGNs) on CTs.Methods: We retrospectively collected the clinical data of 182 patients with GGNs on high resolution CT (HRCT). The CT images of different pixel sizes (0.8mm, 0.4mm, 0.18 mm) were obtained by reconstructing the single HRCT scan using three combinations of field of view and matrix size. For each pixel size setting, radiomic features were extracted for all GGNs and radiomic signatures for the invasiveness of GGNs were built through two modeling pipelines for comparison.Results: The study finally extracted 788 radiomic features. 87% radiomic features demonstrated inter pixel size variation. By either modeling pipeline, the radiomic signature under small pixel size performed significantly better than those under middle or large pixel sizes in predicting the invasiveness of GGNs (p's value