AC Loss of HTS Coil and its Behavior of Magnetic Field
AC Loss of HTS Coil and its Behavior of Magnetic Field
复制标题
高温超导线圈的交流损耗及其磁场行为
DOI:
10.1007/978-4-431-66877-0_222
复制
发表时间:
2000
期刊:
影响因子:
--
通讯作者:
Y. Iwasa
中科院分区:
文献类型:
--
作者:
Y. Sasaki;K. Sawa;Y. Iwasa
We obtained the AC loss of HIS coil wound with Ag sheathed Bi-2223, cooled in liquid nitrogen, from measured voltage and current waveforms. From measured data, effective resistance and inductance were calculated. They vary with amplitude and frequency of AC transport current. In order to search the cause of varying effective inductance, we also measured magnetic field generated by the coil. Behavior of amplitude of magnetic field on several measured points is very similar to that of effective inductance. It is supposed that shield current, which disturbs change of magnetic flux within the coil, might flow in the coil.