Normal Dynamic MRI Enhancement Patterns of the Upper Abdominal Organs: Gadoxetic Acid Compared With Gadobutrol
Normal Dynamic MRI Enhancement Patterns of the Upper Abdominal Organs: Gadoxetic Acid Compared With Gadobutrol
复制标题
DOI:
10.2214/ajr.09.2412
复制
发表时间:
2009-11-01
影响因子:
5
通讯作者:
Puls, Ralf
中科院分区:
文献类型:
--
作者:
Kuehn, Jens-Peter;Hegenscheid, Katrin;Puls, Ralf
OBJECTIVE. The purpose of this study was to investigate whether, at dynamic MRI of the upper abdominal organs, contrast enhancement with gadoxetic acid, a hepatobiliary contrast agent, is comparable with that achieved with an extracellular contrast agent.SUBJECTS AND METHODS. Dynamic gadoxetic acid-enhanced MRI of the pancreas, spleen, kidney, liver, and abdominal aorta was performed on 50 patients; dynamic gadobutrol-enhanced MRI was performed on a control group of 50 patients; and the images were compared. Dynamic imaging with a T1-weighted volumetric interpolated breath-hold examination gradient-echo sequence (TR/TE, 3.35/1.35; flip angle, 12 degrees) was performed before and 20 (arterial phase), 55 (portal venous phase), and 90 (hepatic venous phase) seconds after bolus injection of gadoxetic acid (0.25 mmol/mL) or gadobutrol (1.0 mmol/mL). Signal-to-noise ratios and enhancement indexes were calculated for each organ and time.RESULTS. All MR images in both groups were of diagnostic quality. During the early dynamic phases, significantly lower mean enhancement indexes were found in the gadoxetic acid group than in the gadobutrol group in the pancreas (portal venous phase, 0.66, 1.39, p