文献摘要

被引文献

相似文献

推导了NaI(Tl)闪烁体的60×60响应矩阵,揭示了福岛核反应堆事故尘埃引起的伽马射线脉冲高度分布。展开的能谱提供了有关尘埃场中的放射性和剂量率的信息。通过与其他数据的比较,讨论了估算的放射性活度和剂量率的准确性。
A 60 × 60 response matrix for a NaI( Tl) scintillator was derived to unfold pulse height distributions of gamma rays due to fallout released in the Fukushima nuclear reactor accident. The unfolded energy spectra yielded information concerning radioactivities and dose rates in the fallout field. The accuracy of the evaluated radioactivities and dose rates was discussed by comparing with other data.