ATLAS ITk strip sensor quality control procedures and testing site qualification

ATLAS ITk strip sensor quality control procedures and testing site qualification
复制标题

ATLAS ITk 条形传感器质量控制程序和测试场地资格

DOI:
10.1088/1748-0221/17/12/c12013
复制
发表时间:
2022
影响因子:
1.3
通讯作者:
S. Zenz
S. Zenz
中科院分区:
工程技术4区
文献类型:
--
作者:
M. Mikestikova;A. Affolder;K. Affolder;S. Beaupré;G. Beck;J. Bernabéu;A. Bevan;I. Dawson;A. Dowling;V. Fadeyev;P. Federičová;J. Fernandez;A. Fournier;M. Gignac;G. Greig;J. Gunnell;K. Hara;S. Hirose;B. Hommels;T. Ishii;C. Jessiman;J. Johnson;D. Jones;S. Kachiguin;N. Kang;J. Keller;C. Klein;T. Koffas;J. Kroll;J. Kvasnička;C. Lacasta;V. Latonova;F. Martinez;P. Miyagawa;A. Montalbano;K. Nakamura;L. Poley;D. Rousso;A. Shah;E. Sláviková;C. Solaz;U. Soldevila;E. Staats;T. Stack;B. Stelzer;P. Tůma;M. Ullán;Y. Unno;J. Yarwick;S. Zenz

文献摘要

参考文献

被引文献

相似文献

大型强子对撞机的高亮度升级计划于2029年投入使用,需要用新的全硅内跟踪器取代ATLAS内探测器。辐射硬n+In-p微带硅传感器是由ATLAS内跟踪器条带合作开发的,由Hamamatsu Photonics K.K.生产。总数量为22000个带状传感器的生产已于2020年开始,并将持续到2025年。ATLAS条带传感器协作有责任通过对单个传感器特性进行详细测量,并将获得的结果与制造商进行的测试进行比较,来监控制造设备的质量。制定了专门的质量控制程序,以检查交付的大尺寸传感器是否符合ATLAS规范。执行试生产和生产ATLAS ITK条带传感器的质量控制测试的机构必须首先通过多次高通量测试,才能成功完成现场鉴定过程。文中介绍了质量控制程序和合格评定过程。
The high-luminosity upgrade of the Large Hadron Collider, scheduled to become operational in 2029, requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker. Radiation hard n+-in-p micro-strip silicon sensors were developed by the ATLAS Inner Tracker strip collaboration and are produced by Hamamatsu Photonics K.K. Production of the total amount of 22000 strip sensors has started in 2020 and will continue until 2025. The ATLAS strip sensor collaboration has the responsibility to monitor the quality of the fabricated devices by performing detailed measurements of individual sensor characteristics and by comparing the obtained results with the tests done by the manufacturer. Dedicated Quality Control procedures were developed to check whether the delivered large-format sensors adhere to the ATLAS specifications. The institutes performing the Quality Control testing of the pre-production and production ATLAS ITk strip sensors had to initially be qualified for multiple high-throughput tests by successfully completing the Site Qualification process. The Quality Control procedures and the qualification process are described in this paper.
全尺寸 ATLAS12 传感器的详细研究
DOI: 10.1016/j.nima.2016.03.042
发表时间: 2016
期刊: Accelerators, Spectrometers, Detectors and Associated Equipment
影响因子: --
作者:
Hommels L
通讯作者: Hommels L