Aligning the CMS Muon Chambers with the Muon Alignment System during an Extended Cosmic Ray Run
Aligning the CMS Muon Chambers with the Muon Alignment System during an Extended Cosmic Ray Run
复制标题
在扩展宇宙射线运行期间将 CMS Muon 室与 Muon 对准系统对准
DOI:
--
复制
发表时间:
2009
期刊:
影响因子:
--
通讯作者:
Cms Collaboration
中科院分区:
文献类型:
--
作者:
Cms Collaboration
A BSTRACT : The alignment system for the muon spectrometer of the CMS detector comprises three independent subsystems of optical and analog position sensors. It aligns muon chambers with respect to each other and to the central silicon tracker. System commissioning at full magnetic field began in 2008 during an extended cosmic ray run. The system succeeded in tracking muon detector movements of up to 18 mm and rotations of several milliradians under magnetic forces. Depending on coordinate and subsystem, the system achieved chamber alignment precisions of 140–350 µ m and 30–200 µ rad, close to the precision requirements of the experiment. Systematic errors on absolute positions are estimated to be 340–590 µ m based on comparisons with independent photogrammetry measurements.
影响因子:
1.3
作者:
Collaboration C
通讯作者:
Collaboration C