Thermal design and performance tests of a current limiter with a conduction cooled Nb/sub 3/Sn screen
Thermal design and performance tests of a current limiter with a conduction cooled Nb/sub 3/Sn screen
复制标题
具有传导冷却 Nb/sub 3/Sn 屏的限流器的热设计和性能测试
DOI:
10.1109/77.920274
复制
发表时间:
2001
影响因子:
1.8
通讯作者:
M. Shibuya
中科院分区:
文献类型:
--
作者:
K. Sasaki;A. Yamagata;A. Nii;T. Onishi;M. Shibuya
We examined the possibility of the practical use of a conduction cooled magnetic shield type fault current limiter from the view point of a thermal design. The thermal calculation was carried out with a small model using the Nb/sub 3/Sn wire with low AC loss. We found that the temperature increase of the small model was insignificant. We also confirmed the current limiting operation in an experiment. The conceptual design and the thermal calculation of the conduction cooled fault current limiter for a distribution power system is also discussed in this report.